{"id":4341,"date":"2026-10-01T12:12:07","date_gmt":"2026-10-01T12:12:07","guid":{"rendered":"https:\/\/dev.perimed-instruments.com\/us\/?p=4341"},"modified":"2026-10-08T16:36:45","modified_gmt":"2026-10-08T16:36:45","slug":"the-power-of-combining-laser-doppler-with-tcpo2-one-protocol-multiple-insights","status":"publish","type":"post","link":"https:\/\/dev.perimed-instruments.com\/us\/blog\/the-power-of-combining-laser-doppler-with-tcpo2-one-protocol-multiple-insights\/","title":{"rendered":"The power of combining laser Doppler with TcpO2 \u2014 one protocol, multiple insights"},"content":{"rendered":"\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:20% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" src=\"https:\/\/dev.perimed-instruments.com\/wp-content\/uploads\/Sara-Gyllensporre-Perimed-1024x1024.webp\" alt=\"\" class=\"wp-image-5307 size-full\"\/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"wp-block-paragraph\">by <a href=\"#bio-sg\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\">Sara Gyllensporre<\/mark><\/a><mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\"> <\/mark>(Clinical <em>Application Specialist<\/em>)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In a recent training session with our distributors, I demonstrated a simple yet powerful protocol that combines baseline and provocation measurements for Laser Doppler (LD) perfusion and transcutaneous oxygen (TcpO2).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">LD perfusion measurements are straightforward as they don\u2019t require occlusion; just place the probe and measure. Another aspect is time. Because LD and TcpO2 do not interfere with each other, you can record baselines simultaneously.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The real power, however, comes from the combination of LD, LD with heat provocation, TcpO2, TcpO2 oxygen challenge, and additional TcpO2 provocations to deliver multiple complementary insights into a person\u2019s vascular status.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In this post, I take a closer look at the LD + TcpO2 protocol by briefly explaining the underlying physiology and presenting a couple of example patient cases that show how the individual measurements compare with the combined approach. If you\u2019re interested in using this protocol with PeriFlux 6000, please get in touch by filling out the form at the end of this post.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:24%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\"><div class=\"gn-spacer-block pb-4\">\n    <\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"#book-demo\">Book a demo<\/a><\/div>\n<\/div>\n\n\n<div class=\"gn-spacer-block pb-4\">\n    <\/div>\n<\/div>\n<\/div>\n\n\n<section class=\"relative w-full mx-auto pt-0 pb-0 none\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            <div class=\"acf-innerblocks-container\">\n\n<h3 id=\"h-laser-doppler-in-macro-and-microcirculation-measurements\" class=\"wp-block-heading\">Laser Doppler in macro- and microcirculation measurements<\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66%\">\n<p class=\"wp-block-paragraph\">In traditional <strong>macrocirculation<\/strong> measurements, like ABI and TBI, the laser Doppler probe is usually placed on the toe \u2014 distal to the limb. During cuff inflation, occlusion, and release, the probe measures underlying blood flow, and advanced signal processing identifies when occlusion occurs and when blood flow returns.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Laser Doppler probes can also be used directly without occlusion to assess local cutaneous <strong>microvascular<\/strong> function. In isolation, LD perfusion provides some insight, but when combined with provocations and other microvascular protocols such as TcpO2, its value increases significantly. &nbsp;<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33%\">\n<figure class=\"wp-block-image is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"650\" height=\"800\" src=\"https:\/\/dev.perimed-instruments.com\/wp-content\/uploads\/toe-pressure-2.webp\" alt=\"toe pressure 2\" class=\"wp-image-2794\" style=\"aspect-ratio:0.8125039872408294;width:172px;height:auto\" srcset=\"https:\/\/dev.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/toe-pressure-2.webp 650w, https:\/\/dev.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/toe-pressure-2-244x300.webp 244w\" sizes=\"auto, (max-width: 650px) 100vw, 650px\" \/><\/figure>\n\n\n<div class=\"gn-spacer-block pb-8\">\n    <\/div>\n<\/div>\n<\/div>\n\n<\/div>\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-0 pb-0 none\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            <div class=\"acf-innerblocks-container\">\n\n<h3 id=\"h-the-underlying-physiology\" class=\"wp-block-heading\">The underlying physiology<\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" src=\"https:\/\/dev.perimed-instruments.com\/wp-content\/uploads\/laser-Doppler-baseline-1024x911.webp\" alt=\"\" class=\"wp-image-5743\"\/><figcaption class=\"wp-element-caption\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\"><em>Laser Doppler baseline<\/em><\/mark><\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"wp-block-paragraph\">A laser Doppler probe placed directly on the skin emits low-power laser light into the underlying tissue. Some light is absorbed, and the rest is scattered. When scattered light encounters a stationary structure, it changes direction (illustrated by the orange lines). When scattered light encounters a moving red blood cell (RBC), it changes frequency \u2014 due to the Doppler effect \u2014 as well as direction (illustrated by the blue and green lines). Perfusion is calculated based on the frequency spectrum of the light returning to the probe.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" src=\"https:\/\/dev.perimed-instruments.com\/wp-content\/uploads\/laser-Doppler-heat-provocation-1024x911.webp\" alt=\"\" class=\"wp-image-5745\"\/><figcaption class=\"wp-element-caption\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\"><em>Laser Doppler \u2014 heat provocation<\/em><\/mark><\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"wp-block-paragraph\">When you heat the skin to, for example, 44\u00b0C, the small blood vessels in the tissue dilate, increasing cutaneous microvascular blood flow. In a healthy person, the response is usually immediate, and perfusion typically rises rapidly. In people with impaired microvascular function, this response may be delayed, attenuated, or otherwise impaired.&nbsp;<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:70%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/dev.perimed-instruments.com\/wp-content\/uploads\/TcpO2-LD-heat.webp\" alt=\"\" class=\"wp-image-5754\" style=\"aspect-ratio:2.0483870967741935;width:766px;height:auto\"\/><figcaption class=\"wp-element-caption\"><em><mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\">LD baseline and expected response to heat in a healthy person<\/mark><\/em><\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n<\/div>\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-0 pb-0 none\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            <div class=\"acf-innerblocks-container\">\n\n<h3 id=\"h-interpreting-curves-patient-a\" class=\"wp-block-heading\">Interpreting curves \u2014 Patient A<\/h3>\n\n\n<div class=\"gn-spacer-block pb-8\">\n    <\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" src=\"https:\/\/dev.perimed-instruments.com\/wp-content\/uploads\/patient-A-LD.webp\" alt=\"\" class=\"wp-image-5747\"\/><figcaption class=\"wp-element-caption\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\"><em>LD baseline and heat provocation \u2013 Patient A<\/em><\/mark><\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<p class=\"wp-block-paragraph\"><strong>Patient A<\/strong> responded clearly to heat. Perfusion increased almost immediately after probe heating and plateaued about 10 minutes later.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" src=\"https:\/\/dev.perimed-instruments.com\/wp-content\/uploads\/patient-A-tcpO2.webp\" alt=\"\" class=\"wp-image-5748\"\/><figcaption class=\"wp-element-caption\"><em><mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\">TcpO2 baseline and provocations \u2013 Patient A<\/mark><\/em><\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<p class=\"wp-block-paragraph\">At 42 mmHg, the patient\u2019s baseline was borderline*, suggesting inflammation, edema, or possibly both. However, the patient&#8217;s response to an oxygen challenge showed a clinically significant increase in TcpO2 <mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\"><a href=\"#h-references\" data-type=\"internal\" data-id=\"#h-references\">[1]<\/a><\/mark>, which, together with the strong vasodilatory response observed in the laser Doppler heat measurement, suggests preserved wound-healing potential.<\/p>\n<\/div>\n<\/div>\n\n\n<div class=\"gn-spacer-block pb-11\">\n    <\/div>\n\n\n\n<p class=\"wp-block-paragraph\">*The Global Vascular Guidelines on Chronic Limb-Threatening Ischemia<mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\"> <a href=\"#ref-2\">[2]<\/a> <\/mark>indicate TcpO2 &lt;40 mmHg is associated with increased wound complications. TcpO2 values above this threshold are generally associated with favorable tissue oxygenation.<a id=\"_msocom_1\"><\/a><\/p>\n\n<\/div>\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-0 pb-0 none\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            <div class=\"acf-innerblocks-container\">\n<div class=\"gn-spacer-block pb-11\">\n    <\/div>\n\n\n\n<h3 id=\"h-typical-thresholds-for-ld-with-heat\" class=\"wp-block-heading\">Typical thresholds for LD with heat<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Clinically established LD thresholds comparable to those used for ABI, skin perfusion pressure (SPP), and TcpO2 do not exist. Several factors contribute to this: underlying physiological variation, different measurement technologies, and diverse methods for signal interpretation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In my experience, typical baseline values measured with a PeriFlux 6000 instrument range from 5-50 PU and rise to 100-300 PU during heat provocation. I tend to look at the area under the curve, the percentage increase from baseline to plateau, response time, and the time to peak or plateau, as these reflect microvascular reactivity and vasodilatory capacity.<\/p>\n\n\n<div class=\"gn-spacer-block pb-8\">\n    <\/div>\n\n<\/div>\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-0 pb-0 none\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            <div class=\"acf-innerblocks-container\">\n\n<h3 id=\"h-interpreting-curves-patient-b\" class=\"wp-block-heading\">Interpreting curves \u2014 Patient B<\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" src=\"https:\/\/dev.perimed-instruments.com\/wp-content\/uploads\/patient-B-LD.webp\" alt=\"\" class=\"wp-image-5749\"\/><figcaption class=\"wp-element-caption\"><em><mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\">LD baseline and heat provocation \u2013 Patient B<\/mark><\/em><\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<p class=\"wp-block-paragraph\"><strong>Patient<\/strong> <strong>B <\/strong>had a non-healing wound. The clear lack of response to heat indicates impairment. In such cases, I first validate the measurement by checking that the probe is properly fixed to the skin. Sometimes, I follow up with a second measurement at a different site \u2014 one that hasn&#8217;t been exposed to heat (non-dilated).<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" src=\"https:\/\/dev.perimed-instruments.com\/wp-content\/uploads\/patient-B-tcpO2.webp\" alt=\"\" class=\"wp-image-5750\"\/><figcaption class=\"wp-element-caption\"><em><mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\">LD baseline and heat provocation \u2013 Patient B<\/mark><\/em><\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<p class=\"wp-block-paragraph\"><strong>Patient B&#8217;s<\/strong> TcpO2 baseline was below the generally recommended wound-healing threshold of 40 mmHg, and oxygen response was minimal.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Together, these insights indicate impaired microvascular responsiveness.<\/p>\n<\/div>\n<\/div>\n\n<\/div>\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-0 pb-0 none\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            <div class=\"acf-innerblocks-container\">\n<div class=\"gn-spacer-block pb-11\">\n    <\/div>\n\n\n\n<h3 id=\"h-interpreting-curves-patient-c\" class=\"wp-block-heading\">Interpreting curves \u2014 Patient C<\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" src=\"https:\/\/dev.perimed-instruments.com\/wp-content\/uploads\/patient-C-toe-pressure-TBI.webp\" alt=\"\" class=\"wp-image-5752\"\/><figcaption class=\"wp-element-caption\"><em><mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\">Toe pressure and TBI \u2013 Patient C<\/mark><\/em><\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<p class=\"wp-block-paragraph\"><strong>Patient C <\/strong>is a 90-year-old woman with diabetes, foot discoloration, and low ABI. We first measured toe pressure and TBI. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Taking an average of three toe pressure measurements, at 0.26 on the left and 0.22 on the right, TBI is low.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">At these levels, the findings are suggestive of PAD.**<\/p>\n<\/div>\n<\/div>\n\n\n<div class=\"gn-spacer-block pb-4\">\n    <\/div>\n\n\n\n<p class=\"wp-block-paragraph\">** In the list of recommendations for PAD diagnosis, the IWGDF Guidelines on the Prevention and Management of Diabetic Foot Disease 2023 <mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\"><a href=\"#ref-3\">[3]<\/a><\/mark> states: PAD is less likely in the presence of ABI 0.9-1.3; TBI \u2265 0.70.<\/p>\n\n\n<div class=\"gn-spacer-block pb-11\">\n    <\/div>\n\n\n\n<p class=\"wp-block-paragraph\">To determine the best course of therapy, we followed up with TcpO2, laser Doppler baseline, and a laser Doppler heat provocation. In this case, the patient had no wounds, so we placed the LD probes and TcpO2 electrodes as shown in the illustration below. If a wound is present, I recommend placing these sensors as close to the wound as possible.<\/p>\n\n\n<div class=\"gn-spacer-block pb-4\">\n    <\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:5%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/dev.perimed-instruments.com\/wp-content\/uploads\/cooling-the-probe.webp\" alt=\"\" class=\"wp-image-5858\" style=\"width:30px;height:auto\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:60%\">\n<p class=\"has-btn-background-color has-background wp-block-paragraph\">One of the most important things to remember when carrying out multiple measurements is the probe temperature. A toe pressure measurement heats the probe, so turn off the heat and let the probe cool before performing the baseline laser Doppler measurement.<\/p>\n<\/div>\n<\/div>\n\n\n<div class=\"gn-spacer-block pb-4\">\n    <\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" src=\"https:\/\/dev.perimed-instruments.com\/wp-content\/uploads\/patient-C-LD-TcpO2.webp\" alt=\"\" class=\"wp-image-5751\"\/><figcaption class=\"wp-element-caption\"><em><mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\">LD and TcpO2, baseline and provovations \u2014 Patient C<\/mark><\/em><\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<p class=\"wp-block-paragraph\">Although toe pressure was markedly reduced, baseline limb TcpO2 was above 50 mmHg and comparable to chest-level TcpO2, indicating preserved oxygen delivery. This apparent discrepancy may reflect reduced arterial pressure partly offset by collateral circulation and local blood-flow regulation, allowing the microcirculation to maintain adequate tissue oxygenation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In addition to the low macrovascular indices, the patient had skin discoloration on the left foot. Visually and structurally, the limb looked compromised.<\/p>\n<\/div>\n<\/div>\n\n<\/div>\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-0 pb-0 none\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            <div class=\"acf-innerblocks-container\">\n\n<h3 id=\"h-application-in-clinical-research\" class=\"wp-block-heading\">Application in clinical research<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The combined approach of TcpO2, laser Doppler, and heat provocation may be particularly valuable in studies of peripheral artery disease (PAD), diabetes, wound healing, reconstructive surgery, and other conditions where both oxygen delivery and microvascular responsiveness play important roles. By capturing synchronized physiological data, researchers can investigate whether perfusion changes are accompanied by corresponding changes in tissue oxygenation and explore potential biomarkers of tissue viability and healing potential.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">From a practical perspective, simultaneous measurements also simplify study workflows, reduce examination time, and minimize patient burden.<\/p>\n\n<\/div>\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-0 pb-0 none\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            <div class=\"acf-innerblocks-container\">\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"460\" src=\"https:\/\/dev.perimed-instruments.com\/wp-content\/uploads\/tcpo2_with_periflux_6000-1.webp\" alt=\"\" class=\"wp-image-1277 size-full\" srcset=\"https:\/\/dev.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/tcpo2_with_periflux_6000-1.webp 800w, https:\/\/dev.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/tcpo2_with_periflux_6000-1-300x173.webp 300w, https:\/\/dev.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/tcpo2_with_periflux_6000-1-768x442.webp 768w, https:\/\/dev.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/tcpo2_with_periflux_6000-1-600x345.webp 600w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h3 id=\"h-periflux-6000\" class=\"wp-block-heading\">PeriFlux 6000<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">LD+Heat\/TcpO2 is compatible with our PeriFlux 6000 Combined (laser Doppler and TcpO2) configurations. If you are interested in obtaining a protocol for your instrument, please let me know by filling out the form below.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"#book-demo\">Book a demo<\/a><\/div>\n<\/div>\n<\/div><\/div>\n\n\n<section class=\"relative w-full mx-auto pt-20 pb-20 none\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            <div class=\"acf-innerblocks-container\">\n\n<h6 id=\"h-references\" class=\"wp-block-heading\">References<\/h6>\n\n\n\n<p class=\"wp-block-paragraph\">[1]. Fife, C. E., Smart, D. R., Sheffield, P. J., Hopf, H. W., Hawkins, G., &amp; Clarke, D. (2009). Transcutaneous oximetry in clinical practice: consensus statements from an expert panel based on evidence.&nbsp;<em>Undersea &amp; hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc<\/em>,&nbsp;<em>36<\/em>(1), 43\u201353.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"ref-2\">[2]. Conte, M. S., Bradbury, A. W., Kolh, P., White, J. V., Dick, F., Fitridge, R., Mills, J. L., Ricco, J. B., Suresh, K. R., Murad, M. H., &amp; GVG Writing Group (2019). Global vascular guidelines on the management of chronic limb-threatening ischemia.&nbsp;Journal of Vascular Surgery,&nbsp;69(6S), 3S\u2013125S.e40. <a href=\"https:\/\/doi.org\/10.1016\/j.jvs.2019.02.016\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1016\/j.jvs.2019.02.016<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"ref-3\">[3]. IWGDF Guidelines on the Prevention and Management of Diabetic Foot Disease 2023; lntersocietal 2023 PAD Guidelines <br><a href=\"https:\/\/iwgdfguidelines.org\/wp-contenUuploads\/2023\/07\/IWGDF-2023-05-PAD-Guideline.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/iwgdfguidelines.org\/wp-contenUuploads\/2023\/07\/IWGDF-2023-05-PAD-Guideline.pdf<\/a><\/p>\n\n<\/div>\n        <\/div>\n    <\/section>\n\n<\/div>\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-20 pb-20 none\" id=\"bio-sg\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            <div class=\"acf-innerblocks-container\">\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:20% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" src=\"https:\/\/dev.perimed-instruments.com\/wp-content\/uploads\/Sara-Gyllensporre-Perimed-1024x1024.webp\" alt=\"\" class=\"wp-image-5307 size-full\"\/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.linkedin.com\/in\/sara-gyllensporre-a67591131\/\" target=\"_blank\" rel=\"noreferrer noopener\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\">Sara Gyllensporre<\/mark><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Clinical Application Specialist<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">With over 16 years at Perimed, Sara has held multiple roles and developed a broad understanding of medtech and its application in healthcare settings. She holds a degree in pharmacology and an MSc in molecular biology and plays a vital role in ensuring technology meets the needs of clinical practice, supported by strong relationships with clinicians across Europe.<\/p>\n<\/div><\/div>\n\n<\/div>\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-20 pb-20 none\" id=\"book-demo\">\n                    <div class=\"sec-bg-color absolute top-0 inset-0 flex justify-center overflow-hidden w-full h-full pointer-events-none z-[-2]\"  style=\"background: linear-gradient(90deg, #ffffff 0%, #92c0fd 40%, #4575b6 50%, #92c0fd 60%, #ffffff 100%);;\">\n            <\/div>\n                        \n\n        <div class=\"section__content  max-w-2xl px-4 mx-auto sec_no_tabs\" >\n            <div class=\"acf-innerblocks-container\">\n\n<\/div>\n        <\/div>\n    <\/section>\n\n\n<div class=\"gn-spacer-block pb-8\">\n    <\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Disclaimer<\/strong><br>The views expressed in this blog post are those of the author and do not necessarily represent the official position of Perimed. The content is provided for informational purposes only and is not intended to constitute clinical claims or medical advice. Clinical decisions should always be based on professional judgment and applicable clinical guidelines.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>by Sara Gyllensporre (Clinical Application Specialist) In a recent training session with our distributors, I demonstrated a simple yet powerful protocol that combines baseline and provocation measurements for Laser Doppler (LD) perfusion and transcutaneous oxygen (TcpO2). LD perfusion measurements are straightforward as they don\u2019t require occlusion; just place the probe and measure. Another aspect is &hellip; <a href=\"https:\/\/dev.perimed-instruments.com\/us\/blog\/the-power-of-combining-laser-doppler-with-tcpo2-one-protocol-multiple-insights\/\">Continued<\/a><\/p>\n","protected":false},"author":2,"featured_media":4351,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"_FSMCFIC_featured_image_caption":"","_FSMCFIC_featured_image_nocaption":"","_FSMCFIC_featured_image_hide":"","footnotes":""},"categories":[38],"tags":[],"class_list":["post-4341","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog-post"],"acf":[],"_links":{"self":[{"href":"https:\/\/dev.perimed-instruments.com\/us\/wp-json\/wp\/v2\/posts\/4341","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dev.perimed-instruments.com\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dev.perimed-instruments.com\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dev.perimed-instruments.com\/us\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/dev.perimed-instruments.com\/us\/wp-json\/wp\/v2\/comments?post=4341"}],"version-history":[{"count":6,"href":"https:\/\/dev.perimed-instruments.com\/us\/wp-json\/wp\/v2\/posts\/4341\/revisions"}],"predecessor-version":[{"id":4354,"href":"https:\/\/dev.perimed-instruments.com\/us\/wp-json\/wp\/v2\/posts\/4341\/revisions\/4354"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dev.perimed-instruments.com\/us\/wp-json\/wp\/v2\/media\/4351"}],"wp:attachment":[{"href":"https:\/\/dev.perimed-instruments.com\/us\/wp-json\/wp\/v2\/media?parent=4341"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dev.perimed-instruments.com\/us\/wp-json\/wp\/v2\/categories?post=4341"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dev.perimed-instruments.com\/us\/wp-json\/wp\/v2\/tags?post=4341"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}